I am trying to acquire the data of MPU9250. Supported Operating Systems. For example, if you are using the cRIO-9081, there is a section titled Installing an Operating System in the user manual, which outlines the steps. This rugged, fanless controller features a real-time processor and an FPGA and offers a variety of connectivity ports, including one Ethernet and one serial port. 09-11-2023 06:09 AM. The current system is a cRIO-9074, with LabView Runtime 14. As a starting point, connect the cRIO directly to the host PC. . Steps of the solution: - Make sure to install LabVIEW patches over existing LabVIEW that can be downloaded from our website. Power Connector 3. I have coded with "Front Panel" my application. I have only one module above. View and Download National Instruments CompactRIO cRIO-9072 user manual and specifications online. Unfortunately it seems impossible to find that announcement anymore anywhere. To resolve this issue, work through the troubleshooting steps below: Check that the controller's power supply is working as expected. cRIO-9074. 在网络配置窗口中,单击页面. I have cRIO-9074, Database toolkit. See system specifications on reverse. Please. In NI MAX the cRIO is shown as connected an working. When I'm running the project in LabVIEW appears the following error:Re: cRIO 9074, connect to computer directly. 0およびドライバ をインストールする. On its System Settings tab, click the Update Firmware button. By dumping air l simply mean opening at a desired voltages. I have enabled the second ethernet port of the cRio with a static IP address in the same subnet as the DAQ system. 02-22-2021 10:02 AM. I am using the 2nd Ethernet port on the cRIO-9074 for monitoring of the system and it works in development mode but when I create an executable and deploy it to run at startup I can not connect to the port. I have cRIO-9074 with following modules: - NI-9421 (1) – 7 safety signals from inductive sensors according of position of DFWD units; - NI-9421 (2) – 5 safety signals from inductive sensors according of position of DFWD units and “start” signal; - NI-9472 (1) – 8 commands signals for motors and hydraulic. Next thing the vi would not run anymore. Return to Home Page;. 12-27-2013 01:38 AM. Software on target and PC are now identical. The RT code can execute in a few microseconds, the scan engine updates every 10ms, but the 9211 has a scan rate of 14 scans/second. 215 and unchanged. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 使用以太网电缆将 cRIO-9074 以太网端口 1 连接到与主机 PC 相同的网络。 从开始 » 程序 » National Instruments » Measurement & Automation启动 NI Measurement & Automation Explorer (MAX)。双击左侧配置面板树中的远程系统以自动发现网络上的 cRIO-9074,然后单击 CompactRIO 控制器。 3. We selected NI cRIO-9073 and NI cRIO-9074 controllers, an NI 9871 serial interface module, an NI 9208 analog input module, an NI 9426 digital input module, and an NI 9476 digital output module. I assume that reloading LV would also create a new. To install handles on both ends of a chassis or controller, you must purchase two kits. The NI cRIO-9074 integrated system features an industrial 400 MHz real-time processor and an eight-slot chassis with an embedded, reconfigurable 2M gate FPGA. 4. Featured with 128 MB DRAM, 400 MHz CPU, and 256 MB Internal Storage, the National Instruments cRIO-9074 (Part. Re: compiler errror 6 now vi run bad on cRio. I see the following warning on my project explorer: "Unsupported Item: LabVIEW currently cannot load the selected item. 0. 783832-02. NI MAX. The PS-15 is an industrial power supply that is. cRIO Shared Variable after Reboot. - Details Display Dialog. vi under my FPGA Target and run the. all worked great. Aerospace, Defense, & Government. telnetliquid-llc (3259) 100% positive feedback. This page documents all the applicable standards and certifications for the cRIO-9074 and provides downloadable certifications. opt file in Spartan-3, however its avaliable in vertex-5 and that too when i try to change manually it says access denied!默认用户名为 admin ,默认密码为空,因此请将该空格留空。. Note the default login for cRIOs is user: admin. Member. Running into exactly the same issues. 2. It will hit your boundary (the 9074 has 128MB) and then cease signal and drop to 0. I have a unit running for over 5 years almost everyday which consists of a NI cRIO 9074 and two (2) NI 9144 EtherCAT modules. 10-10-2011 04:53 AM. $199. We are trying to retrieve an image from a NI cRIO 9074. 1. I am working with Labview 2018 and I have a NI cRIO-9074 chassis. Trying to do this with the 9403, I have run headlong into the well-documented. Re: driver rio 9074. Ho controllato il rapporto MAX del tuo cRIO e attualmente hai la versione 19. Cannot complete build because following VI loaded broken: C:NILV2012PCB2CodeMain. 8-Slot, 400 MHz CPU, 128 MB DRAM, 256 MB Storage, 2M Gate FPGA CompactRIO Controller (Legacy)—The cRIO‑9074 is an embedded controller ideal for advanced control and monitoring applications. Member. Then select EtherCAT in the pull-down box under Mode and. Reset Button 8. NI CompactRIO 20. I have a stepper motor drived by NI 9512 and cRIO 9074. 포트 및 커넥터 cRIO-9035은(는) 다음 포트와 커넥터를 제공합니다. ikaiser. Free postage. This standard architecture helps improve the time. Now MAX appears to have limited connectivity to the. The reason you are seeing this is because your controller may not be compatible with your LabVIEW version. You will need the RealTime toolkit to work with the 9074, and optionally the FPGA toolkit to write custom FPGA code for the FPGA chip. Press firmly on the connector side of the I/O module until the latches lock the I/O module into place. It runs the NI Linux Real-Time operating system with access to the I/O through NI-DAQmx drivers or with the LabVIEW FPGA module. 198944-02L. Then select EtherCAT in the pull-down box under Mode and click OK. 0. The CAN1 port on 9853 is designed to be used with a powered CAN bus. We use a client app on a Windows. Thanks. Home Support Documentation Product Certifications cRIO-9074 Product Certifications. In my project i am aquiring the voltage value across the sensor using CRIO-9074 and convert that voltage to temperature using the RTD function and store the value in array. g. Ok, turns out all I had to do was open a file explorer on my PC, and type in ftp://192. I configure the CRio as a EtherCAT master (maybe the problem is here. CompactRIO-904x and CompactRIO-905x Series: NI-DAQmx is compatible with the cRIO-904x and cRIO-905x families of controllers. gshockxcc. I'm trying to use a Schneider LXM32 servo drive coupled to a NI cRIO 9074 Ethercat master. 5. Comprar 782415-01 - Ni - Controlador, CompactRIO, cRIO-9074, 400MHz, 128MB RAM, Disco Duro 256 MB, 8 Ranuras, Temp. The source code used to conduct these tests has been attached below. In LabVIEW I want to start a measurements to measure a force with a sensor which is connected to NI 9219. I have found many LabVIEW codes using the myRIO but there are very less resources regarding cRIO. Options. University of Technology Eindhoven. 5 e precedenti del driver CompactRIO, secondo questo documento. NI-PS-14/15/16/17 Panel Mount Brackets Installation Guide. Hello, I am trying to power cRIO-9074 out of its box, however, the status light continues blinking. Use this guide to select the correct power connector for your CompactRIO Controller. RJ-45 Ethernet Port 2 (cRIO-9074 Only) 4. Beginning in April 2009 for cRIO-9074 controllers and January 2010 for cRIO-9073 controllers, new controllers will feature automatic network connection. Best regards, GerdW using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019 0 Kudos Message 6 of 7 (1,690 Views) Reply. It offers Intel Atom dual-core processing, an Artix-7 FPGA, and four slots for C Series modules. Power Connector 7. lvproj. Options. Have bought a Kollmorgen AKD, and cRIO 9074. vi. Click on Advanced Ethernet Settings in the lower right-hand corner. We are using a cRIO-9074 with a NI 9220 to measure analogue signales and a NI 9474 to trigger deigital outputs. Hello, I want to connect my cRIO-9074 with my PXI System. This rugged, fanless controller features a real-time processor and an FPGA and offers a variety of connectivity ports, including one Ethernet. The cRIO‑9024 does not include. CompactRIO systems feature a controller with a processor running a. Repeat these steps to install additional I/O modules. 8-Slot, 400 MHz CPU, 128 MB DRAM, 256 MB Storage, 2M Gate FPGA CompactRIO Controller (Legacy)—The cRIO‑9074 is an embedded controller ideal for advanced. Options. The CompactRIO controllers (cRIO 9002, 9004, 9081 and 9082) use the Pharlap or WES7 operating system, which NI-CAN Supports. Vector Signal Transceivers. In MAX, if you right click the software section of your cRIO device and select add/remove software, there will be an option for NI Veristand RT Engine 2010. Removing I/O Modules from the ChassisProblem of rebooting NI cRIO 9074. Sappster. SMB Connector (cRIO-9074 Only) 6. Solution. Complete the following steps to connect a power supply to the chassis. Figure 1. 0 e 2009) reinstallando soltanto il 2009, ma mi trovo ancora con lo stesso problema. 07 ATEX 0626664X and is IECEx UL 14. NI 951x cRIO Axis Communication Module Host HMI and Axis Settings: LabVIEW Project Windows RIO Hardware CompactRIO with NI Scan Engine NI 951x C Series Module(s) NI 951x EtherCAT Axis Communication Module EtherCAT C Series Chassis NI 951x C Series Module(s) cRIO Chassis User VI NI SoftMotion APIs EtherCAT with NI Scan Engine NI SoftMotion. This rugged, fanless controller features a real-time processor and an FPGA and offers a variety of connectivity ports, including one Ethernet and one serial port. cRIO-9048 1:POWER2:STATUS 1 Left Side Attachment (If Compatible) Right Side Attachment Align Chassis Ground Connection Up (If Compatible) Note Some NI controller/chassis designs allow for carrying handles on either end of the product. NI PS-14/15/16/17 Letter of Volatility. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy) —The cRIO‑9024 is an embedded real-time controller ideal for advanced control and monitoring applications. g. Hi, I'm transferring a project from LabVIEW 2012 to LabVIEW 2016(64-bit) on windows 10, with an interface with cRio-9074. NI software installs VC2015 Runtime and. 5 or later; LabVIEW. The new cRIO-9072 and cRIO-9074 systems extend the family of NI FPGA-based deployment platforms, including PXI, PC and standard CompactRIO hardware that share a standard embedded hardware architecture combining a powerful floating-point processor, a reconfigurable FPGA and I/O modules. e. Dear all, I am trying to establish a communication between a CRio 9074 and a MaxPos Maxon drive over EtherCAT. Programming information for the VXT PXIe Vector Transceiver models M9410A, M9411A, and M9415A. The controller incorporates one Ethernet port and one Serial port. Open the example project file cRIO-901x SMB DIO. I am pretty frustrated because I completely do not know wha. Check under Remote Systems in MAX for the cRIO-9074. Hi Sithu, You are right. the Power Requirements section. We recently were collecting data and the cRIO 9074 device was able to deploy just fine the program. Sto usando un cRIO 9074 con pn 192172 e la versione dei drivers è 3. See full list on knowledge. Beyond jitter, note that you will be able to see a substantial performance improvements in loop rates with the NI Linux Real-Time based cRIO-9068 over the cRIO-9024 and cRIO-9074 controllers and with the cRIO-903x controllers over the previous generation cRIO-9025. - Format the controller, open NI-MAX, select your controller and from the right-click menu select Format disk. Power on the cRIO by plugging the power back in (continue to hold the RESET button while powering on) Wait until the status light turns on, then release the RESET button. 0. In a CompactDAQ system, a chassis is connected to your PC through USB or Ethernet, and then populated with one or more conditioned I/O modules for direct sensor connectivity. The cRIO-9067 is a rugged, fanless, embedded controller that you can use for advanced control and monitoring applications. Dont want to build a robot, no trajectories or synchronised motions, just want a R&D labbench setup to drill a hole, just like drilling a hole in the wall at home with a DIY tool. For a list of what minimum software and driver versions are needed for the modules listed, please refer to the following link: Software Support for CompactRIO,. Start with an empty project, add an RT CompactRIO Target (9073) to the project by type (offline), configure the IP and try to Connect to it (do not add the chassis). The hardware includes the NI Real-Time PXI controller, CompactRIO, Single-Board RIO, and Expansion Chassis. 1994 Honda acty kei 4wd truck. 4. If the VI loads as expected but errors are still detected during the build, contact National Instruments technical support for assistance. To boot, my predecessors left close to no documentation on how it was originally set up. 06-14-2010 04:26 AM. Re: Proportional and Servo Valve Control by using NI 9264 and cRIO 9014. Connect the cRIO-9074 directly to the host PC via a generic Ethernet cable or an Ethernet crossover cable. This rugged, fanless controller features a real-time processor and an FPGA and offers a variety of connectivity ports, including one Ethernet and one. C is connected to 0V. Port Angeles, WA. My controller code has 3 parallel processes (for 3 banks in my controller) that each contain 3 while loops. Any help is very much appreciated. . The original system was a cRIO-9073, developed with LabView 2009. I'm trying to connect Arduino uno (with BNO055) with CRIO 9074(real time). Complete the following steps to connect a power supply to the. Coding_Badly October 13, 2011, 6:00am 2. The new NI cRIO-9076 integrated system contains a 400 MHz real-time processor, a four-slot chassis with an embedded, reconfigurable LX45 FPGA chip, and a The new cRIO-9072 integrated system combines an industrial 266 MHz real-time processor and an eight-slot chassis with an embedded, reconfigurable 1M gate FPGA chip. 10-14-2010 04:43 AM. Now I will show the software system as well as my procedure to make my project. LEDs 2. Disconnect the device from power and from the computer. 2 version of cRIO PB Master/Slave driver and 4. I wanted to know how we can store the voltage data that we get from CRIO-9074 in. Options. lvproj. The ideal power supply for this purpose is the PS-15. Turns out, the cRio had assigned itself a new IP address and all modules disappeared. The same method can only be controlled in sub-millisecond level, and the clock offset fluctuates within 10us. I can get data from an hygrometer using the RS232 port with the following format T75. Cannot regulate velocity of AKD controlled by cRIO through Interactive Test Panel. To configure the controller to synchronize to an SNTP server, go through the following steps: 1. CRIO2. 在NI-MAX中,选择目标后单击工具栏上的登录按钮,然后输入用户名和密码。. 1. NI 9234 module represents a 4-channel, ±5 V, 24-Bit IEPE module for vibration. Member 09-03-2014 03:46 PM. This standard architecture helps improve the time. Repeat these steps to install additional I/O modules. The cRIO-9074 is an embedded controller ideal for advanced control and monitoring applications. 5. Hirarki antara komputer host dengan cRIO Ni 9074 Gambar 2. Active Participant 10-18-2017 11:29 AM. 0 Kudos Message 3 of 3National Instruments NI CRIO-9074 - 8-slot chassis CompactRIO. 1. cRIO-9012 cRIO-9014 cRIO-9022 cRIO-9023 cRIO-9024 cRIO-9025 cRIO-9063 cRIO-9064 cRIO-9065 cRIO-9066 cRIO-9067 cRIO-9068 cRIO-9072 cRIO-9073 cRIO-9074 cRIO-9075 cRIO-9076 cRIO-9081 cRIO-9082: N/A: N/A: Cable & Accessories for C Series Module with D-Sub connection; Chassis: SD Card: SD Card Slot Door:If you are unable to connect the cRIO to the LabVIEW project, please refer to Failed to Connect to the Target When Using a CompactRIO in LabVIEW. If a remote system target does not appear in MAX, enable the IP RESET DIP switch on the controller, reboot the controller, and then disable the IP RESET DIP switch. 0 as device driver). 2. Connect the positive lead of the power supply to the V terminal of the power connector. The new National Instruments cRIO-9076 integrated system contains a 400 MHz real-time processor, a four-slot chassis with an embedded, reconfigurable LX45 FPGA chip. The cRIO-904x controllers are the first. Order by Part Number or Request a Quote. Re: LV 20. The cRIO-9072/9073/9074 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO Certificate No. Update with NI MAX: Open NI MAX. Thus, NI-9881 is not supported when used in cRIO-910x or cRIO-907x reconfigurable chassis but only in cRIO-911x chassis or in cRIO-903x, 904x, 905x, 906x and 908x. This tutorial uses a cRIO-9074 CompactRIO Controller as the EtherCAT master and NI-9144 as the EtherCAT slave. DIP Switches This document describes how to connect the cRIO-9072/9073/9074 to a network and how to use the features of the cRIO-9072/9073/9074. Solution. When trying to install "NI serial 9870 and 9871 scan engine support" on CRIO it says that it requires "NI rio io scan 1. I do not have access to the labview FPGA package, only the RT module and scan engine. But MAX will not show the modules in the cRIO chassis. DIP Switches This document describes how to connect the cRIO-9072/9073/9074 to a network and how to use the features of the cRIO-9072/9073/9074. 置crio-9022 使其启动后打开嵌入式独立应用程序的配置方法,见labview帮助。 注: 要配置crio-9022,必须连接以太网端口1。不能通过以太网端口 2 配 置控制器。 rs-232 串口 crio-9022 有一个rs-232 串口,可连接显示器或输入设备。通过串口vi 可读写串口数 据。默认用户名为 admin ,默认密码为空,因此请将该空格留空。. I am currently in possession of a cRIO-9074, as well as a NI-9403 DIO module. •cRIO 9074 Real-Time Controller and Chassis •NI 9211 Thermocouple . Con el módulo de Real-Time podrás usar este cRIO en modo Scan Interface. Options: - Upgrade your. 2 version of cRIO PB Slave driver. 254. We know there are plenty of differences when it comes to used equipment and quite often, choosing between different pieces is difficult. 1) before deployment i. I have been working on a data acquisition project, where I record arrays of sensor data (both boolean and analog) with only simple arithmetic from the following modules mounted on a cRIO-9074: The modules and cRIO were all purchased from legitimate. Buying used equipment doesn't always have to be a shot in the dark. The required module, driver, or plug-in either is not inst. zip linked below that contains the example project. I only have "NI rio io scan 1. 09-06-2019 08:28 AM. This rugged, fanless controller features a. DASYLab. Working with NI cRIO 9145 Apex_Waves. Order by Part Number or Request a Quote. 4. The National Instruments CompactRIO Controller, cRIO-9074, is an embedded controller that is. Disconnect the device from power and from the computer. I've got a cRIO 9074, and LabVIEW with the Real Time Module. I'm using a NI cRIO 9074 with a NI 9221 Analog input card to get the signal of an accelerometer sensor. Rearranging them on the cRIO does not bring them back, delete and update view in MAX does not work. The software architecture is organized as folows: 1) the FPGA vis acquire the data 2) the real time vi has a controller running in a high priority timed loop and a lower priority timed loop sends the data by TCP/IP to a host PC;3) the host PC vi receives and stores the data. xls is attached at the end of this white paper to help you approximate the entire system loop rate if you are only using NI. Hi, I am trying to use cRIO 9074 to collect data from different sensors at 50Hz and log the data to SD card plugged in 9802 module. Bonjour à tous, Je travaille avec un cRio 9074 sous labview 2018 mais suite à une mise à jour logiciel qui a planté, impossible de s'y connecter. After modifying the code, I was unable to Run at Startup, probably due to a license issue. Re: cRIO-9074 cannot connect. 0. Options. If we reboot the device the network work and even if we do not touch anything, sometimes the network start working again. a reset will not put the IP settings back to the default (factory) state. 09-22-2021 06:23 AM. Active Participant. I am working on a Temperature sensor(PT100) that uses CRIO-9074 and i/o module 9381. The new National Instruments cRIO-9076 integrated system contains a 400 MHz real-time processor, a four-slot chassis with an embedded, reconfigurable LX45 FPGA chip. 4. ホームページに戻る; Toggle navigation. Thus your power supply will work fine to just power the controller and FPGA backplane. 2. To install handles on both ends of a chassis or controller, you must purchase two kits. I am trying to determine if there is execution safety in unticking the option before deployment upon cRIO or other embedded stand-alone solutions. Price: $1,287. NI FPGAハードウェア (RIO、Rシリーズなど) で使用するLabVIEW FPGAコードをローカルでコンパイルする場合や、コンパイルツールのローカルインストールが必要なLabVIEW FPGAの機能を使用する場合には、正しいバージョンのXilinxコンパイルツールをインストールする必要があります。通常、必要なXilinx. 0 Kudos Message 3 of 11 (3,195 Views) Reply. The 9072/9073/9074 must have the console out rocker switch enabled. 0089X certified. I've started with Modbus Communication Reference Example for cRIO and I've changed the example project to work with my hardware. I am working on a real time application with a cRIO 9074 and two NI 9201 C-Series module, in LabView 2014 Professional system. Set up. The cRIO-9074 will attempt to establish a DHCP network connection when connected to a network and powered up under the following conditions: First power up; After the hard drive is formattedThe NI-Industrial Communications for EtherCAT software provides an EtherCAT master driver to support the real-time EtherCAT network operations. I am using CRIO 9074 controller and NI 9516 as drive interface module. 您可以通过两种方式登录实时控制器,包括Measurement and Automation Explorer或网络设置。. 33 GHz Dual-Core CPU, 2 GB. cRIO-9048 1:POWER2:STATUS 1 Left Side Attachment (If Compatible) Right Side Attachment Align Chassis Ground Connection Up (If Compatible) Note Some NI controller/chassis designs allow for carrying handles on either end of the product. FTP the ni-rt. One reads an array of FXP values from an FPGA DMA FIFO and pushes that array into a queue. Find complete product documentation to learn how to get. Once NI-CAN is installed on the development machine, it must also be installed onto the CompactRIO from Measurement & Automation Explorer (MAX). 0およびドライバ をインストールしてLabVIEWで使用するには、以下の手順に従ってください。 特定のハードウェアデバイスをサポートするソフトウェアバージョンを確認するには、「サポートされているハードウェアとソフトウェア. CompactRIO cRIO-9072 controller pdf manual download. We checked the accelerometer with an oscilloscope, that's OK. Note: When the controller’s Ethernet Port 2 is in EtherCAT mode, you cannot use that port on an Ethernet network. 더 자세한 정보는 LabVIEW 도움말의 Using the Embedded UI to Access RT Target VIs 토픽을 참조하십시오. 02-08-2022 11:32 PM. or Best Offer. 0 address or it will try to initiate a DHCP server connection. 1, quindi viene rispettata la compatibilità secondo la matrice che mi hai linkato. I am also connecting 3. For taking a first look at the measured values i used the NI distributed system manager. I have configured the ethernet ports on the cRIO-9074 according to this tutorial: "KnowledgeBase 4E0DGASK: Configuring the Dual Ethernet Ports on Real-Time Controllers". This page provides dimensional drawings for the cRIO-9074. cRIO-9024 Front Panel 1 3 6 7 4 2 8 9 5 1. 0, etc. In order to figure out the synchronization performance under cross platform circumstances, this article use IEEE 1588-2008 protocol as synchronization time reference to implement a sync DAQ task between a PXIe platform and a cRIO-904X platform. Author. Open the example project file cRIO-901x SMB DIO. 6 about 2 years in advance. Ending Tuesday at 8:46AM PDT 2d 8h. Right-click the cRIO Target and select Properties. I have the kit crio 9074 and i am using it in scan mode. 05-05-2011 12:38 AM. The location for all firmware files is <Program. The new cRIO-9072 and cRIO-9074 systems extend the family of NI FPGA-based deployment platforms, including PXI, PC and standard CompactRIO hardware that share a standard embedded hardware architecture combining a powerful floating-point processor, a reconfigurable FPGA and I/O modules. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Real-Time FlexRIO. Aerospace, Defense, and Government. Each device is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -20 °C ≤ Ta ≤ 55 °C. This cRIO unit was recently installed as an upgrade to an original FieldPoint system. The PXI System is connected with my Network through the. 選択したハードウェアとドライバの組み合わせ. The included device driver communicates with the firmware to help you set up and control how the compatible. Then, after complete one data collection, the cRIO suddenly stopped connecting in Labview. The cRIO-9074 is equipped with a RT processor and an FPGA. crio-9074 이더넷 포트 2(기본이 아닌 mac 주소)를 선택합니다. Marketplace is a convenient destination on Facebook to discover, buy and sell. Like I mentioned I have a cRio 9074 and 2 NI9401. NI PS-15 Power Supply User Manual. Insertion Groove 2. Well, when I wrote a test script to make an LED blink, it kept blinking after I disconnected my laptop. however, the ip address keeps to be 169. Since it is an electronic device, the cRIO-9074 requires a DC power supply to work. Solution. Try disconnecting the cRio from the PC and connecting it solely to the Laptop, do any of the settings appear? 2. 3V and GND to the sensor's VDD and GND for achieving I2C communication. Products. com National Instruments cRIO-9074 CompactRIO Controller. Archiving TC samples to disk faster than 14Hz results in duplicate data. Then select EtherCAT in the pull-down box under Mode and click OK. The software architecture is organized as folows: 1) the FPGA vis acquire the data 2) the real time vi has a controller running in a high priority timed. 0. I am in charge of configuring it but till today I was unsuccessful. Digital I/O. CompactRIO Reconfigurable Chassis: NI cRIO-9111, NI cRIO-9112, NI cRIO-9113, NI cRIO-9114, cRIO-9116, and cRIO-9118. This article explains how to restore an NI Linux Real-Time device to the factory default configuration. Most of these examples are developed before NI-RIO 2.